diff options
author | Akinori Hattori <hattya@gentoo.org> | 2018-07-04 22:19:12 +0900 |
---|---|---|
committer | Akinori Hattori <hattya@gentoo.org> | 2018-07-04 22:23:47 +0900 |
commit | d789b6541c11824fe6c54368c7dd14416d463bed (patch) | |
tree | 18be1281b23990fc5daa414dfeb6c82551f21cdd | |
parent | www-servers/h2o: specify ruby version (diff) | |
download | gentoo-d789b6541c11824fe6c54368c7dd14416d463bed.tar.gz gentoo-d789b6541c11824fe6c54368c7dd14416d463bed.tar.bz2 gentoo-d789b6541c11824fe6c54368c7dd14416d463bed.zip |
www-servers/h2o: update init script
Closes: https://bugs.gentoo.org/655468
Package-Manager: Portage-2.3.40, Repoman-2.3.9
-rw-r--r-- | www-servers/h2o/files/h2o.initd | 54 |
1 files changed, 20 insertions, 34 deletions
diff --git a/www-servers/h2o/files/h2o.initd b/www-servers/h2o/files/h2o.initd index ad598a5f6199..b100434bd20e 100644 --- a/www-servers/h2o/files/h2o.initd +++ b/www-servers/h2o/files/h2o.initd @@ -1,51 +1,37 @@ #!/sbin/openrc-run -# Copyright 1999-2017 Gentoo Foundation +# Copyright 1999-2018 Gentoo Foundation # Distributed under the terms of the GNU General Public License v2 -extra_commands="configtest" +extra_commands="checkconfig" extra_started_commands="reload" -description="An optimized HTTP/1.x, HTTP/2 server" -description_configtest="Run H2O' internal config check" -description_reload="Reload the H2O configuration or upgrade the binary without losing connections" -: ${config:="/etc/h2o/h2o.conf"} -pidfile=$(grep pid-file "${config}" | cut -d' ' -f2) +description_checkconfig="Check the configuration file" +description_reload="Reload the configuration file" +: ${h2o_config:="/etc/${RC_SVCNAME}/${RC_SVCNAME}.conf"} + +start_stop_daemon_args="--group ${RC_SVCNAME}" +command="/usr/bin/${RC_SVCNAME}" +command_args="-m daemon -c \"${h2o_config}\"" +pidfile="$(grep pid-file "${h2o_config}" | cut -d' ' -f2-)" name="H2O" -command="/usr/bin/h2o" -command_args="-m daemon -c ${config}" -required_files="$config" depend() { - use net - after logger + need net + use dns } -start_pre() { - if [ "${RC_CMD}" != "restart" ]; then - configtest || return 1 - fi +checkconfig() { + "${command}" -m test -c "${h2o_config}" || return 1 } -stop_pre() { - if [ "${RC_CMD}" = "restart" ]; then - configtest || return 1 - fi +start_pre() { + checkconfig || return 1 } reload() { - configtest || return 1 - ebegin "Refreshing ${name} configuration" - kill -HUP $(cat ${pidfile}) &>/dev/null - eend $? "Failed to reload ${name}" -} - -configtest() { - ebegin "Checking ${name} configuration" - - if ! ${command} -c ${config} -t &>/dev/null; then - ${command} -c ${config} -t - fi - - eend $? "Failed, please correct the errors above" + checkconfig || return 1 + ebegin "Reloading ${name:-${RC_SVCNAME}}" + start-stop-daemon --signal HUP --pidfile "${pidfile}" + eend ${?} } |