# Copyright 1999-2019 Gentoo Authors
# Distributed under the terms of the GNU General Public License v2
EAPI=6
AT_M4DIR="config"
inherit eutils multilib
DESCRIPTION="Provides Remote-Console and System Management Software as per IPMI v1.5/2.0"
HOMEPAGE="https://www.gnu.org/software/freeipmi/"
MY_P="${P/_/.}"
S="${WORKDIR}"/${MY_P}
[[ ${MY_P} == *.beta* ]] && ALPHA="-alpha"
SRC_URI="mirror://gnu${ALPHA}/${PN}/${MY_P}.tar.gz"
LICENSE="GPL-3"
SLOT="0"
KEYWORDS="amd64 hppa x86"
IUSE="debug nagios"
RDEPEND="dev-libs/libgcrypt:0"
DEPEND="${RDEPEND}
virtual/os-headers"
RDEPEND="${RDEPEND}
nagios? (
|| ( net-analyzer/icinga net-analyzer/nagios )
dev-lang/perl
)
"
src_configure() {
local myeconfargs=(
$(use_enable debug)
--disable-static
--disable-init-scripts
--localstatedir=/var
)
econf "${myeconfargs[@]}"
}
# There are no tests
src_test() { :; }
src_install() {
default
# freeipmi by defaults install _all_ commands to /usr/sbin, but
# quite a few can be run remotely as standard user, so move them
# in /usr/bin afterwards.
dodir /usr/bin
for file in ipmi{detect,ping,power,console}; do
mv "${D}"/usr/{s,}bin/${file} || die
# The default install symlinks these commands to add a dash
# after the ipmi prefix; we repeat those after move for
# consistency.
rm "${D}"/usr/sbin/${file/ipmi/ipmi-}
dosym ${file} /usr/bin/${file/ipmi/ipmi-}
done
# Install the nagios plugin in its proper place, if desired
if use nagios; then
dodir /usr/$(get_libdir)/nagios/plugins
mv "${D}"/usr/share/doc/${PF}/contrib/nagios/nagios_ipmi_sensors.pl \
"${D}"/usr/$(get_libdir)/nagios/plugins/ || die
fperms 0755 /usr/$(get_libdir)/nagios/plugins/nagios_ipmi_sensors.pl
insinto /etc/icinga/conf.d
newins "${FILESDIR}"/freeipmi.icinga freeipmi-command.cfg
fi
dodoc AUTHORS ChangeLog* DISCLAIMER* NEWS README* TODO doc/*.txt
keepdir \
/var/cache/ipmimonitoringsdrcache \
/var/lib/freeipmi \
/var/log/ipmiconsole
# starting from version 1.2.0 the two daemons are similar enough
newinitd "${FILESDIR}"/bmc-watchdog.initd.4 ipmidetectd
newconfd "${FILESDIR}"/ipmidetectd.confd ipmidetectd
newinitd "${FILESDIR}"/bmc-watchdog.initd.4 bmc-watchdog
newconfd "${FILESDIR}"/bmc-watchdog.confd bmc-watchdog
newinitd "${FILESDIR}"/bmc-watchdog.initd.4 ipmiseld
newconfd "${FILESDIR}"/ipmiseld.confd ipmiseld
}
|