blob: 7d7155d29bb21203c75e37c246d901c13b071c12 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
|
# Copyright 1999-2021 Gentoo Authors
# Distributed under the terms of the GNU General Public License v2
EAPI="7"
inherit systemd optfeature
DESCRIPTION="A lightweight system monitoring tool"
HOMEPAGE="https://www.monitorix.org/"
SRC_URI="https://www.monitorix.org/${P}.tar.gz"
LICENSE="GPL-2+"
SLOT="0"
KEYWORDS="amd64 ~x86"
IUSE=""
RDEPEND="
acct-user/monitorix
acct-group/monitorix
dev-perl/Config-General
dev-perl/DBI
dev-perl/HTTP-Server-Simple
dev-perl/IO-Socket-SSL
dev-perl/libwww-perl
dev-perl/MIME-Lite
dev-perl/XML-Simple
net-analyzer/rrdtool[graph,perl]
dev-perl/CGI"
src_prepare() {
# Put better Gentoo defaults in the configuration file.
sed -e "s|\(base_dir.*\)/usr/share/${PN}|\1/usr/share/${PN}/htdocs|" \
-e "s|\(secure_log.*\)/var/log/secure|\1/var/log/auth.log|" \
-e "s|nobody|${PN}|g" -i ${PN}.conf || die
# Update systemd binary location
sed -e "s|/usr/bin|/usr/sbin|g" -i docs/${PN}.service || die
eapply_user
}
# Override compile phase
src_compile() { :; }
src_install() {
dosbin ${PN}
newinitd "${FILESDIR}/monitorix" ${PN}
insinto /etc/monitorix
doins ${PN}.conf
keepdir /etc/${PN}/conf.d
insinto /etc/logrotate.d
newins docs/${PN}.logrotate ${PN}
dodoc Changes README{,.nginx} docs/${PN}-{alert.sh,apache.conf,lighttpd.conf}
doman man/man5/${PN}.conf.5
doman man/man8/${PN}.8
insinto /var/lib/${PN}/www
doins logo_bot.png logo_top.png ${PN}ico.png
keepdir /var/lib/${PN}/www/imgs
fowners monitorix:monitorix /var/lib/${PN}/www/imgs
exeinto /var/lib/${PN}/www/cgi
doexe ${PN}.cgi
exeinto /usr/lib/${PN}
doexe lib/*.pm
keepdir /var/lib/${PN}/usage
insinto /var/lib/${PN}/reports
doins -r reports
systemd_dounit docs/${PN}.service
}
pkg_postinst() {
optfeature "disk drive temperatures and health" app-admin/hddtemp
optfeature "email reports/statics" mail-mta/postfix mail-mta/sendmail
optfeature "lm-sensors and GPU temperatures" sys-apps/lm-sensors
optfeature "APC UPS statistics" sys-power/apcupsd
optfeature "Network UPS Tools statistics" sys-power/nut
elog
elog "If you wish to use your own web server:"
elog " Web data can be found at: ${EROOT}/var/lib/${PN}/www/"
elog " Also please check the correct user and group ownership"
elog " of ${EROOT}/var/lib/${PN}/www/imgs/"
}
|